Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
1.
JACC Heart Fail ; 11(8 Pt 1): 865-878, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37269258

RESUMEN

Late right heart failure (RHF) is increasingly recognized in patients with long-term left ventricular assist device (LVAD) support and is associated with decreased survival and increased incidence of adverse events such as gastrointestinal bleeding and stroke. Progression of right ventricular (RV) dysfunction to clinical syndrome of late RHF in patients supported with LVAD is dependent on the severity of pre-existing RV dysfunction, persistent or worsening left- or right-sided valvular heart disease, pulmonary hypertension, inadequate or excessive left ventricular unloading, and/or progression of the underlying cardiac disease. RHF likely represents a continuum of risk with early presentation and progression to late RHF. However, de novo RHF develops in a subset of patients leading to increased diuretic requirement, arrhythmias, renal and hepatic dysfunction, and heart failure hospitalizations. The distinction between isolated late RHF and RHF due to left-sided contributions is lacking in registry studies and should be the focus of future registry data collection. Potential management strategies include optimization of RV preload and afterload, neurohormonal blockade, LVAD speed optimization, and treatment of concomitant valvular disease. In this review, the authors discuss definition, pathophysiology, prevention, and management of late RHF.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Disfunción Ventricular Derecha , Humanos , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Sistema de Registros , Ventrículos Cardíacos , Disfunción Ventricular Derecha/epidemiología
3.
Eur J Cardiothorac Surg ; 63(5)2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-36912728

RESUMEN

OBJECTIVES: Early right-sided heart failure (RHF) was seen in 22% of recipients of a left ventricular assist device (LVAD) in the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). However, the optimal treatment of post-LVAD RHF is not well known. Levosimendan has proven to be effective in patients with cardiogenic shock and in those with end-stage heart failure. We sought to evaluate the efficacy of levosimendan on post-LVAD RHF and 30-day and 1-year mortality. METHODS: The EUROMACS Registry was used to identify adults with mainstream continuous-flow LVAD implants who were treated with preoperative levosimendan compared to a propensity matched control cohort. RESULTS: In total, 3661 patients received mainstream LVAD, of which 399 (11%) were treated with levosimendan pre-LVAD. Patients given levosimendan had a higher EUROMACS RHF score [4 (2- 5.5) vs 2 (2- 4); P < 0.001], received more right ventricular assist devices (RVAD) [32 (8%) vs 178 (5.5%); P = 0.038] and stayed longer in the intensive care unit post-LVAD implant [19 (8-35) vs 11(5-25); P < 0.001]. Yet, there was no significant difference in the rate of RHF, 30-day, or 1-year mortality. Also, in the matched cohort (357 patients taking levosimendan compared to an average of 622 controls across 20 imputations), we found no evidence for a difference in postoperative severe RHF, RVAD implant rate, length of stay in the intensive care unit or 30-day and 1-year mortality. CONCLUSIONS: In this analysis of the EUROMACS registry, we found no evidence for an association between levosimendan and early RHF or death, albeit patients taking levosimendan had much higher risk profiles. For a definitive conclusion, a multicentre, randomized study is warranted.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Adulto , Humanos , Corazón Auxiliar/efectos adversos , Simendán , Puntaje de Propensión , Estudios Retrospectivos , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/cirugía , Sistema de Registros , Resultado del Tratamiento
4.
ESC Heart Fail ; 9(5): 3469-3482, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35880515

RESUMEN

AIMS: Continuous-flow left ventricular assist devices (CF-LVADs) have become a standard of care in end-stage heart failure. Limited data exist comparing outcomes of HeartMate3 (HM3) and HeartWare HVAD (HW). We aimed to compare midterm outcomes of these devices. METHODS AND RESULTS: Investigator-initiated retrospective-observational comparative analysis of all patients who underwent primary LVAD implantation of either HM3 or HW at our centre between January 2010 and December 2020. Data were derived from a prospective registry. Primary endpoints were all-cause mortality and heart transplantation. Secondary endpoints included device-related major adverse cardiac and cerebrovascular events, which included major bleeding, major neurological dysfunction (defined as persisting neurological impairment for ≥24 h), device-related major infection (excluding driveline infections), major device malfunctions leading to re-intervention or partial device exchange (pump failure, outflow-graft twist or failure, controller failure, battery failure, patient cable failure, but excluding pump thrombosis), and pump thrombosis. Further secondary endpoints included right heart failure, gastrointestinal bleeding, driveline infections, and surgical re-interventions. The secondary outcomes were analysed not only for the first event but also for recurrent events. The analysis included competing risks analysis and recurrent event regression analysis, with adjustment for confounders age, gender, body mass index (BMI), and Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) level. Out of 106 primary CF-LVAD implantations, 36 (34%) received HM3 and 70 (66%) received HW. Median follow-up was 1.48 years [interquartile range 0.67, 2.41]. HM3 was more often implanted in men (91.7% vs. 72.9%, P = 0.024); patients were older (median 61 years [54, 66.5] vs. 52.5 years [43, 60], P < 0.001), had a higher BMI (median 26.7 kg/m2 [23.4, 29.0] vs. 24.3 kg/m2 [20.7, 27.4], P = 0.013), had more comorbidities, and were more likely targeted for destination therapy (36.1% vs. 14.3%, P = 0.010). Death occurred in 33.3% of HM3 patients, compared with 22.9% of HW patients, P = 0.247 (probability of survival at 4 years, 54.7% vs. 74.1%, P = 0.296). After adjustment for confounders, we observed a significant six-fold risk increase in device malfunctions for HW [hazard ratio (HR) 6.49, 95% confidence interval (CI) [1.89, 22.32], P = 0.003], but no significant differences in pump thrombosis (P = 0.173) or overall survival (P = 0.801). CONCLUSIONS: Comparing midterm outcomes between HM3 and HW for LVAD support from a prospective registry, HW patients had a significantly higher risk of device malfunctions. No significant differences were evident between devices in overall survival and in respect to most outcomes.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Trombosis , Masculino , Humanos , Estudios Retrospectivos , Corazón Auxiliar/efectos adversos , Ventrículos Cardíacos , Trombosis/etiología
5.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-35150247

RESUMEN

OBJECTIVES: In the third report of the European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery, outcomes of patients receiving mechanical circulatory support are reviewed in relation to implant era. METHODS: Procedures in adult patients (January 2011-June 2020) were included. Patients from centres with <60% follow-ups completed were excluded. Outcomes were stratified into 3 eras (2011-2013, 2014-2017 and 2018-2020). Adverse event rates (AERs) were calculated and stratified into early phase (<3 months) and late phase (>3 months). Risk factors for death were explored using univariable Cox regression with a stepwise time-varying hazard ratio (<3 vs >3 months). RESULTS: In total, 4834 procedures in 4486 individual patients (72 hospitals) were included, with a median follow-up of 1.1 (interquartile range: 0.3-2.6) years. The annual number of implants (range: 346-600) did not significantly change (P = 0.41). Both Interagency Registry for Mechanically Assisted Circulatory Support class (classes 4-7: 23, 25 and 33%; P < 0.001) and in-hospital deaths (18.5, 17.2 and 11.2; P < 0.001) decreased significantly between eras. Overall, mortality, transplants and the probability of weaning were 55, 25 and 2% at 5 years after the implant, respectively. Major infections were mainly noted early after the implant occurred (AER<3 months: 1.44 vs AER>3 months: 0.45). Bilirubin and creatinine levels were significant risk factors in the early phase but not in the late phase after the implant. CONCLUSIONS: In its 10 years of existence, EUROMACS has become a point of reference enabling benchmarking and outcome monitoring. Patient characteristics and outcomes changed between implant eras. In addition, both occurrence of outcomes and risk factor weights are time dependent.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Cirugía Torácica , Procedimientos Quirúrgicos Torácicos , Adulto , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Sistema de Registros , Resultado del Tratamiento
6.
J Cardiopulm Rehabil Prev ; 42(2): 97-102, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34753874

RESUMEN

PURPOSE: The aim of this study was to investigate changes in exercise capacity (EC) and quality of life (QoL) of patients with ventricular assist devices (VADs) during cardiac rehabilitation (CR). METHODS: Data from patients with VAD implantation and subsequent CR between 2007 and 2017 were analyzed retrospectively. Measures of the 6-min walk test [6MWT] distance, Functional Independence Measure [FIM], ergometry, MacNew Heart Disease Questionnaire [MNH], and Hospital Anxiety and Depression Scale [HADS] at entry and discharge were examined. RESULTS: Data from 110 patients (age 53 ± 12 yr; male 82%) were analyzed. Patients improved during CR significantly in the 6MWT (114 ± 85 m, P < .001), ergometry (20 ± 17 W, P = .002), FIM (8 ± 7 points, P < .001), and MNH (0.8 ± 0.7 points, P < .001). Initial HADS levels were high with a mean value of 9 and did not improve during CR (-0.4 ± 5 points, P = .637). Significant differences of improvements in the 6MWT were observed between left and biventricular VAD (129 ± 90 m vs 85 ± 67 m, P = .043) as well as destination therapy and bridge-to-transplant (184 ± 88 m vs 102 ± 82 m, P = .005). CONCLUSIONS: Patients with VAD implantation had statistically and clinically significant improvements in EC and QoL as assessed with the MNH during CR. Patients on destination therapy showed a larger benefit from CR than bridge-to-transplant patients and patients with left VAD improved more than biventricular VAD patients.


Asunto(s)
Rehabilitación Cardiaca , Insuficiencia Cardíaca , Corazón Auxiliar , Adulto , Anciano , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Estudios Retrospectivos , Prueba de Paso
7.
J Card Surg ; 36(7): 2558-2561, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33880792

RESUMEN

The 7-year long-term survival after Aspergillus fumigatus mediastinitis after heart transplantation, an uncommonly described condition, is herein reported. A 66-year-old male developed an infection with A. fumigatus covering the entire thoracic cavity with a fungal turf after orthotopic heart transplantation. Repeated surgical removal of infectious and necrotic tissue together with innovative topical treatment using voriconazole and chlorhexidine combined with systemic antifungal treatment, helped in controlling the infection. Definitive wound closure was achieved by standard sternal refixation and latissimus dorsi muscle flap plasty. Survival after A. fumigatus mediastinitis after heart transplantation was achieved with sequential debridement in combination with topical application of antifungal agents.


Asunto(s)
Aspergilosis , Trasplante de Corazón , Mediastinitis , Anciano , Aspergilosis/tratamiento farmacológico , Aspergillus , Humanos , Masculino , Mediastinitis/tratamiento farmacológico , Mediastinitis/etiología , Infección de la Herida Quirúrgica/tratamiento farmacológico , Resultado del Tratamiento , Voriconazol
8.
J Cardiothorac Surg ; 16(1): 64, 2021 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-33789723

RESUMEN

BACKGROUND: In Switzerland, long-term circulatory support programs have been limited to heart transplant centers. In 2014, to improve the management of patients with end-stage heart failure not eligible for transplantation, we implemented a left ventricular assist device (LVAD) program for destination therapy at the University Hospital of Basel. METHODS: We described the program set-up with practical aspects. Patients aged 65 and above with therapy refractory end-stage heart failure without major contraindication for LVAD implantation were included. Younger patients with bridge-to-candidacy profile were also considered. Using the Kaplan-Meier estimate, we retrospectively analyzed the overall survival and freedom from major adverse events after LVAD implantation. We compared our results to internationally reported data. RESULTS: Between October 2014 and September 2019, 16 patients received an LVAD in our center. The mean age at implantation was 67.1 years. The mean EuroSCORE II was 24.4% and the median INTERMACS level was 4. Thirteen patients received an LVAD as destination therapy and three patients as bridge-to-candidacy. The overall survival was 87.5 and 70% at 1 and 2 years, respectively. Freedom from stroke was 81.3% at 1 and 2 years. Freedom from device infection was 67.7 and 58.7% at 1 and 2 years, respectively. Freedom from gastrointestinal bleeding was 75 and 56.3% at 1 and 2 years, respectively. Freedom from readmission was 50 and 31.3% and at 6 months and 1 year, respectively. CONCLUSIONS: The Basel experience demonstrated the possible implementation of an LVAD program for destination therapy or bridge-to-candidacy in a non-transplant comprehensive heart-failure center with midterm survival results and freedom from major adverse events comparable to international registries. Patient selection remains crucial. TRIAL REGISTRATION: This study was registered on the ClinicalTrials.gov database ( NCT04263012 ).


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Anciano , Femenino , Estudios de Seguimiento , Trasplante de Corazón , Corazón Auxiliar/efectos adversos , Hospitales Universitarios , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Falla de Prótesis , Estudios Retrospectivos , Accidente Cerebrovascular/prevención & control , Suiza
9.
ESC Heart Fail ; 8(2): 1096-1105, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33417294

RESUMEN

AIMS: Heart transplantation (HTx) results in complete autonomic denervation of the donor heart, causing resting tachycardia and abnormal heart rate (HR) responses to exercise. We determined the time course of suggestive cardiac reinnervation post HTx and investigated its clinical significance. METHODS AND RESULTS: Heart rate kinetics during standard cardiopulmonary exercise testing at 2.5-5 years after HTx was assessed in 58 patients. According to their HR increase 30 s after exercise onset, HTx recipients were classified as denervated (slow responders: <5 beats per minute [b.p.m.]) or potentially reinnervated (fast responders: ≥5 b.p.m.). Additionally, in 30 patients, longitudinal changes of maximal oxygen consumption and HR kinetics were assessed during the first 15 post-operative years. At 2.5-5 years post HTx, 38% of our study population was potentially reinnervated. Fast responders were significantly younger (41 ± 15 years) than slow responders (53 ± 13 years, P = 0.003) but did not differ with regard to donor age, immunosuppressive regime, cardiovascular risk factors, endomyocardial biopsy, or vasculopathy parameters. While HR reserve (56 ± 20 vs. 39 ± 15 b.p.m., P = 0.002) and HR recovery after 60 s (15 ± 11 vs. 5 ± 6 b.p.m., P < 0.001) were greater in fast responders, resting HR, peak HR of predicted, and peak oxygen consumption of predicted were comparable. CONCLUSIONS: Signs of reinnervation occurred mainly in younger patients. Maximal oxygen consumption was independent of HR kinetics.


Asunto(s)
Prueba de Esfuerzo , Trasplante de Corazón , Frecuencia Cardíaca , Humanos , Cinética , Estudios Longitudinales , Donantes de Tejidos
10.
Eur J Cardiothorac Surg ; 59(1): 207-216, 2021 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-33038216

RESUMEN

OBJECTIVES: Data on the impact and course of uncorrected tricuspid regurgitation (TR) during left ventricular assist device (LVAD) implantation are scarce and inconsistent. This study explores the clinical impact and natural course of uncorrected TR in patients after LVAD implantation. METHODS: The European Registry for Patients with Mechanical Circulatory Support was used to identify adult patients with LVAD implants without concomitant tricuspid valve surgery. A mediation model was developed to assess the association of TR with 30-day mortality via other risk factors. Generalized mixed models were used to model the course of post-LVAD TR. Joint models were used to perform sensitivity analyses. RESULTS: A total of 2496 procedures were included (median age: 56 years; men: 83%). TR was not directly associated with higher 30-day mortality, but mediation analyses suggested an indirect association via preoperative elevated right atrial pressure and creatinine (P = 0.035) and bilirubin (P = 0.027) levels. Post-LVAD TR was also associated with increased late mortality [hazard ratio 1.16 (1.06-1.3); P = 0.001]. On average, uncorrected TR diminished after LVAD implantation. The probability of having moderate-to-severe TR immediately after an implant in patients with none-to-mild TR pre-LVAD was 10%; in patients with moderate-to-severe TR pre-LVAD, it was 35% and continued to decrease in patients with moderate-to-severe TR pre-LVAD, regardless of pre-LVAD right ventricular failure or pulmonary hypertension. CONCLUSIONS: Uncorrected TR pre-LVAD and post-LVAD is associated with increased early and late mortality. Nevertheless, on average, TR diminishes progressively without intervention after an LVAD implant. Therefore, these data suggest that patient selection for concomitant tricuspid valve surgery should not be based solely on TR grade.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia de la Válvula Tricúspide , Adulto , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/epidemiología , Insuficiencia de la Válvula Tricúspide/cirugía
12.
Intensive Care Med ; 46(7): 1349-1360, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32016536

RESUMEN

PURPOSE: The aim of the study was to analyze early mortality after continuous-flow left ventricular assist device (LVAD) implantation which remains high. METHODS: We analyzed consecutive (n = 2689) patients from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) undergoing continuous-flow LVAD implantation. The primary outcome was early (< 90 days) mortality. Secondary outcomes were differential causes of early post-operative death following LVAD implantation. RESULTS: Univariable and multivariable analysis as well as regression analysis were used to examine determinants and differential causes of early (< 90 days) mortality after LVAD implantation. During the first 90 days, 2160 (80%) patients were alive with ongoing LVAD support, 40(2%) patients underwent heart transplantation, and 487(18%) deceased. The main causes of early death were MOF (36%), sepsis (28%), cardiopulmonary failure (CPF; 10%), CVA (9%), and right-sided heart failure (RHF, 8%). Furthermore, MOF and sepsis are 70% of causes of death in the first week. Independent clinical predictors of early death were age, female sex, INTERMACS profile 1 to 3, and ECMO. Laboratory predictors included elevated serum creatinine, total bilirubin, lactate, and low hemoglobin. Furthermore, hemodynamic predictors included elevated RA-to-PCWP ratio, pulmonary vascular resistance, and low systemic vascular resistance. Longer total implantation time was also independent predictor of early mortality. A simple model of 12 variables predicts early mortality following LVAD implantation with a good discriminative power with area under the curve of 0.75. CONCLUSIONS: In the EUROMACS registry, approximately one out of five patients die within 90 days after LVAD implantation. Early mortality is primarily dominated by multiorgan failure followed by sepsis. A simple model identifies important parameters which are associated with early mortality following LVAD implantation.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Femenino , Humanos , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
13.
ESC Heart Fail ; 7(2): 714-720, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31994838

RESUMEN

Coronary fibromuscular dysplasia is uncommon, and even rarer its unstable and recurrent course. We present the unique case of a 52-year-old woman who underwent in total 12 coronary angiographies and three percutaneous coronary intervention within 24 months because of repetitive acute coronary syndromes due to refractory spasm, dissection, restenosis all leading to end-stage heart failure, and heart transplantation. The patient died 12 days after the heart transplantation complicated by intraoperative acute thrombotic occlusion of left anterior descending artery of the graft despite normal pretransplant coronary angiography. Autopsy of the recipient heart confirmed coronary fibromuscular dysplasia with massive intimal hyperplasia and restenosis.


Asunto(s)
Displasia Fibromuscular , Insuficiencia Cardíaca , Trasplante de Corazón , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Femenino , Displasia Fibromuscular/complicaciones , Displasia Fibromuscular/diagnóstico , Insuficiencia Cardíaca/etiología , Humanos , Persona de Mediana Edad
14.
Eur J Cardiothorac Surg ; 56(6): 1037-1045, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31369075

RESUMEN

OBJECTIVES: The purpose of this study was to describe pre- and postoperative data from the EUROMACS registry with regard to indications, for and survival and complication rates of patients with primary continuous flow and pulsatile biventricular long-term assist devices (BiVADs) versus total artificial hearts (TAHs) or left ventricular assist devices (LVADs) + short-term right ventricular assist device (RVAD) implants. METHODS: We investigated patients who received implants between 1 January 2011 and 21 October 2017. Clinical baseline information about comorbidities, laboratory results, medical and device therapies and echocardiographic, haemodynamic and right ventricle (RV) parameters were evaluated along with the rates of deaths and complications. RESULTS: A total of 413 of 3282 patients (12.5%) needed a biventricular pump. We investigated 37 long-term BiVADs, 342 LVAD + short-term RVAD implants and 34 TAHs. Minor differences were found in the baseline characteristics of our population, which had an overall high morbidity profile. The 1-year survival rate was 55% for patients with a continuous flow BiVAD; 52% for patients with an LVAD + short-term RVAD; 37% for patients with pulsatile BiVADs; and 36% for patients with a TAH. No statistical difference was observed among the groups. Over 50% of patients with BiVAD support were classified as INTERMACS profiles 1 and 2. The percent of patients with ambulatory heart failure (INTERMACS 4‒7) undergoing BiVAD implants was modest at <15%. No patients with a pulsatile BiVAD (n = 15) or a TAH (n = 34) were implanted as destination therapy, but 27% of the patients with continuous flow BiVADs (n = 6) and 23% of the patients with LVAD + short-term RVAD (n = 342) were implanted as 'destination'. The adverse events profile remained high, with no significant difference among pump types. The right ventricular stroke work index and right heart failure scores indicated poor RV function in all groups. After 3 months of LVAD + short-term RVAD support, 46.7% still required ongoing support, and only 18.5% were weaned from RVAD support; 33.1% died. CONCLUSIONS: The mortality rate after BiVAD support was high. Survival rates and adverse events were statistically not different among the investigated groups. In the future, composite study end points examining quality of life and adverse events beyond survival may help in shared decision-making prior to general mechanical circulatory support, particularly in patients with BiVAD implants.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Corazón Artificial , Adulto , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/mortalidad , Procedimientos Quirúrgicos Cardíacos/estadística & datos numéricos , Comorbilidad , Femenino , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/cirugía , Corazón Artificial/efectos adversos , Corazón Artificial/estadística & datos numéricos , Corazón Auxiliar/efectos adversos , Corazón Auxiliar/estadística & datos numéricos , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Falla de Prótesis , Sistema de Registros , Estudios Retrospectivos , Disfunción Ventricular/epidemiología , Disfunción Ventricular/mortalidad , Disfunción Ventricular/cirugía
15.
Eur J Cardiothorac Surg ; 56(6): 1081-1089, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31321431

RESUMEN

OBJECTIVES: Tricuspid regurgitation (TR) is common in patients receiving a left ventricular assist device (LVAD). Controversy exists as to whether concomitant tricuspid valve surgery (TVS) is beneficial in currently treated patients. Therefore, our goal was to investigate the effect of TVS concomitant with a LVAD implant. METHODS: The European Registry for Patients with Mechanical Circulatory Support was used to identify adult patients. Matched patients with and without concomitant TVS were compared using a propensity score matching strategy. RESULTS: In total, 3323 patients underwent LVAD implantation of which 299 (9%) had TVS. After matching, 258 patients without TVS were matched to 258 patients with TVS. In the matched population, hospital deaths, days on inotropic support, temporary right ventricular assist device implants and hospital stay were comparable, whereas stay in the intensive care unit was higher in the TVS cohort (11 vs 15 days; P = 0.026). Late deaths (P = 0.17), cumulative incidence of unexpected hospital readmission (P = 0.15) and right heart failure (P = 0.55) were comparable between patients with and without concomitant TVS. In the matched population, probability of moderate-to-severe TR immediately after surgery was lower in patients with concomitant TVS compared to patients without TVS (33% vs 70%; P = 0.001). Nevertheless, the probability of moderate-to-severe TR decreased more quickly in patients without TVS (P = 0.030), resulting in comparable probabilities of moderate-to-severe TR within 1.5 years of follow-up. CONCLUSIONS: In matched patients, TVS concomitant with LVAD implant does not seem to be associated with better clinical outcomes. Concomitant TVS reduced TR significantly early after LVAD implant; however, differences in probability of TR disappeared during the follow-up period.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Corazón Auxiliar , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide/cirugía , Femenino , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Corazón Auxiliar/efectos adversos , Corazón Auxiliar/estadística & datos numéricos , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Readmisión del Paciente/estadística & datos numéricos , Puntaje de Propensión , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/epidemiología , Insuficiencia de la Válvula Tricúspide/cirugía
16.
Eur J Cardiothorac Surg ; 56(2): 230-270, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31100109

RESUMEN

Long-term mechanical circulatory support (LT-MCS) is an important treatment modality for patients with severe heart failure. Different devices are available, and many-sometimes contradictory-observations regarding patient selection, surgical techniques, perioperative management and follow-up have been published. With the growing expertise in this field, the European Association for Cardio-Thoracic Surgery (EACTS) recognized a need for a structured multidisciplinary consensus about the approach to patients with LT-MCS. However, the evidence published so far is insufficient to allow for generation of meaningful guidelines complying with EACTS requirements. Instead, the EACTS presents an expert opinion in the LT-MCS field. This expert opinion addresses patient evaluation and preoperative optimization as well as management of cardiac and non-cardiac comorbidities. Further, extensive operative implantation techniques are summarized and evaluated by leading experts, depending on both patient characteristics and device selection. The faculty recognized that postoperative management is multidisciplinary and includes aspects of intensive care unit stay, rehabilitation, ambulatory care, myocardial recovery and end-of-life care and mirrored this fact in this paper. Additionally, the opinions of experts on diagnosis and management of adverse events including bleeding, cerebrovascular accidents and device malfunction are presented. In this expert consensus, the evidence for the complete management from patient selection to end-of-life care is carefully reviewed with the aim of guiding clinicians in optimizing management of patients considered for or supported by an LT-MCS device.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Atención Perioperativa/métodos , Implantación de Prótesis/métodos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Humanos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/terapia , Implantación de Prótesis/instrumentación
17.
Pharmacogenomics J ; 19(1): 53-64, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-29282365

RESUMEN

New Onset Diabetes after Transplantation (NODAT) is a frequent complication after solid organ transplantation, with higher incidence during the first year. Several clinical and genetic factors have been described as risk factors of Type 2 Diabetes (T2DM). Additionally, T2DM shares some genetic factors with NODAT. We investigated if three genetic risk scores (w-GRS) and clinical factors were associated with NODAT and how they predicted NODAT development 1 year after transplantation. In both main (n = 725) and replication (n = 156) samples the clinical risk score was significantly associated with NODAT (ORmain: 1.60 [1.36-1.90], p = 3.72*10-8 and ORreplication: 2.14 [1.39-3.41], p = 0.0008, respectively). Two w-GRS were significantly associated with NODAT in the main sample (ORw-GRS 2:1.09 [1.04-1.15], p = 0.001 and ORw-GRS 3:1.14 [1.01-1.29], p = 0.03) and a similar ORw-GRS 2 was found in the replication sample, although it did not reach significance probably due to a power issue. Despite the low OR of w-GRS on NODAT compared to clinical covariates, when integrating w-GRS 2 and w-GRS 3 in the clinical model, the Area under the Receiver Operating Characteristics curve (AUROC), specificity, sensitivity and accuracy were 0.69, 0.71, 0.58 and 0.68, respectively, with significant Likelihood Ratio test discrimination index (p-value 0.0004), performing better in NODAT discrimination than the clinical model alone. Twenty-five patients needed to be genotyped in order to detect one misclassified case that would have developed NODAT 1 year after transplantation if using only clinical covariates. To our knowledge, this is the first study extensively examining genetic risk scores contributing to NODAT development.


Asunto(s)
Diabetes Mellitus/etiología , Diabetes Mellitus/genética , Trasplante de Órganos/efectos adversos , Adolescente , Adulto , Anciano , Estudios de Cohortes , Femenino , Genotipo , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Adulto Joven
18.
Am J Transplant ; 19(1): 238-246, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-29920932

RESUMEN

New-onset diabetes mellitus after transplantation (NODAT) is a complication following solid organ transplantation (SOT) and may be related to immune or inflammatory responses. We investigated whether single nucleotide polymorphisms (SNPs) within 158 immune- or inflammation-related genes contribute to NODAT in SOT recipients. The association between 263 SNPs and NODAT was investigated in a discovery sample of SOT recipients from the Swiss Transplant Cohort Study (STCS, n1  = 696). Positive results were tested in a first STCS replication sample (n2  = 489) and SNPs remaining significant after multiple test corrections were tested in a second SOT replication sample (n3  = 156). Associations with diabetic traits were further tested in several large general population-based samples (n > 480 000). Only SP110 rs2114592C>T remained associated with NODAT in the STCS replication sample. Carriers of rs2114592-TT had 9.9 times (95% confidence interval [CI]: 3.22-30.5, P = .00006) higher risk for NODAT in the combined STCS samples (n = 1184). rs2114592C>T was further associated with NODAT in the second SOT sample (odds ratio: 4.8, 95% CI: 1.55-14.6, P = .006). On the other hand, SP110 rs2114592C>T was not associated with diabetic traits in population-based samples, suggesting a specific gene-environment interaction, possibly due to the use of specific medications (ie, immunosuppressants) in transplant patients and/or to the illness that may unmask the gene effect.


Asunto(s)
Diabetes Mellitus/etiología , Diabetes Mellitus/genética , Inflamación/genética , Trasplante de Órganos , Polimorfismo de Nucleótido Simple , Receptores de Trasplantes , Adolescente , Adulto , Anciano , Diabetes Mellitus/inmunología , Femenino , Interacción Gen-Ambiente , Heterocigoto , Homocigoto , Humanos , Terapia de Inmunosupresión , Inmunosupresores/uso terapéutico , Inflamación/inmunología , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Estudios Prospectivos , Suiza/epidemiología , Adulto Joven
19.
PLoS One ; 13(8): e0202950, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30148864

RESUMEN

BACKGROUND: The purpose of the present study was to assess the short- and long-term progression of cardiac allograft vasculopathy (CAV) using serial 3-vessel quantitative coronary angiography (QCA). METHODS: CAV progression was assessed using serial 3-vessel QCA analysis at baseline, 1-year and long-term angiographic follow-up (8.5±3.7 years) after heart transplantation. The change in minimal lumen diameter (MLD) and percent diameter stenosis (%DS) was serially assessed within matched segments. Patients were graded according to the ISHLT-CAV classification and grouped as ISHLT-CAV0 and ISHLT-CAV1-3. The primary endpoint was mean change in MLD and %DS. RESULTS: A total of 41 patients and 520 matched segments were available for serial 3-vessel QCA. Overall, MLD decreased non-significantly from baseline to 1-year follow-up and significantly from 1-year to the long-term angiographic follow-up (Δ-0.08mm/year [95%CI -0.11 to -0.05], P<0.001). %DS increased significantly from baseline to 1-year (Δ+0.96%/year [95%CI 0.04 to 1.88], P = 0.041) and from 1-year to long-term angiographic follow-up (Δ+0.61%/year [95%CI 0.33 to 0.88], P<0.001). ISHLT-CAV1-3 at 1 year and at long-term angiographic follow-up was observed in 22% and 61%, respectively. Between baseline and long-term angiographic follow-up, a significant reduction in MLD was observed within both groups without a significant difference in the reduction between the two groups (ISHLT-CAV0: median -0.49mm [IQR -0.54 to -0.43] vs. ISHLT-CAV1-3: median -0.40mm [IQR -0.44 to -0.35], P = 0.4). CONCLUSION: The current data suggest that QCA can't predict CAV beyond 1 year, but, QCA affirmed that CAV progresses to a similar extent in patients who do not develop visual CAV during long-term follow-up.


Asunto(s)
Continuidad de la Atención al Paciente , Angiografía Coronaria/métodos , Oclusión de Injerto Vascular/diagnóstico por imagen , Cardiopatías/cirugía , Trasplante de Corazón/efectos adversos , Complicaciones Posoperatorias/diagnóstico por imagen , Enfermedades Vasculares/diagnóstico por imagen , Adulto , Aloinjertos , Técnicas de Imagen Cardíaca/métodos , Progresión de la Enfermedad , Femenino , Oclusión de Injerto Vascular/etiología , Rechazo de Injerto/etiología , Rechazo de Injerto/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Medición de Riesgo , Enfermedades Vasculares/etiología
20.
J Heart Lung Transplant ; 37(6): 685-691, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29550146

RESUMEN

The second annual IMACS registry report includes over 14, 000 patients from 35 countries. Survival, adverse events, and an updated risk model is presented. Continuous flow pumps continue to dominate the world's experience. One and Two-year survival remains at 80% and 70%. Congenital heart disease and biventricular support are the most dominant risk factors. The database is poised for major novel analyses.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Adulto , Anciano , Informes Anuales como Asunto , Femenino , Insuficiencia Cardíaca/mortalidad , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...